9 Custom Abutments with Porcelain fused to  Zirconia Bridge

A  pre-op diagnostic guide for patient approval was manufactured. The case was approved and the guide was later converted to a surgical guide with barium sulphate to be used with CBCT scan for guided implant surgery.

A digital impression using the iTero intra-oral scanner was taken of 9 implants. The case was manufactuCZ3539redfrom this one digital impression. The final custom abutments were manufactured to maintain the tissue and support healing. A full anatomical verification index was manufactured using our in house EnvisionTec Perfactory to determine midline, and crown length. The zirconia framework was tried in to verify fit and the case was finished for the next appointment.

 

 

 

Pre op diagnostic converted to a barium sulfate surgical guide

Pre op diagnostic converted to a barium sulfate surgical guide

Implant Scan

Implant Scan

Custom abutments

Custom abutments

Verification index

Printed verification index

Zirconia framework

Zirconia framework

Zirconia framework tryin, full arch

Zirconia framework tryin, full arch

Milled poyurethane model. Dies milled and are the same as the abutment

Milled poyurethane model. Dies milled and are the same as the abutment

DSCN3539

Finished bridge

More photos showing the digital design steps of this case using our 5  AXIS Designer